Your industrial partner for chromatography instruments

image11

Technology

Technology is rapidly evolving and our engineers are at the leading edge of innovative hardware and processes that manage ever higher yields and more precise separation requirements. Breakthroughs in moving from batch to continuous processing methods promise to offer widespread benefits in both cost and safety.  Our engineers are at the forefront of today's developments, and can help you to optimize your processes while increasing quality and control. 

image12

Our production with your design

We develop and supply OEM and custom systems for biotechnology and pharmaceutical customers who seek to take advantage of the benefits offered by our highly skilled workforce and procedure driven fabrication techniques.

image13

Optimize Performance, Minimize Downtime

Have you ever been frustrated by the quality of the liquid chromatography (LC) equipment on the market? So have we. That’s why you choose Inscinstech.

Unique PUMP

Key features and benefits:

  

Analytical、semi-preparative and preparative purifications:

– the wide flow range of the Unique Pump (up to 300 mL/min) perfectly supports standard, semi-preparative and preparative applications. 

Fast and precise gradients 

– The Unique Pump is the perfect choice for fast and precise gradients using LC, Prep LC, GPC, FPLC systems etc.

Self-Flush

- Provide continuous washing of the piston, without additional pump, gravity feed arrangement or manual flush. be used to improve seal life.

Biocompatibility: 

– Wetted material: Peek, Sapphire, ruby, UHMWPE.

– Dynamic mixer: Can be pause

The best solution for FPLC solvent delivery:

Up to 3 Pressure sensors: 

–System pressure sensor, Pre-Column sensor, post-column pressure sensor, integrated into the column valve to protect the column and media from over pressure. One pressure sensor measures the pressure before the column to protect the column hardware. Another sensor measures the pressure after the column and calculates the pressure difference over the packed media bed. If one of the pressures exceeds the preset limit, the run can be paused. Alternatively, the user can activate pressure flow regulated mode, which automatically decreases the flow rate when the pressure exceeds the preset limit. Pressure sensors are also connected to the system and sample pumps to protect the connected columns and instrument hardware.

up to 3 air sensors: 

–Enable the safe exclusion of air from the system. Integrated air sensors are placed in the sample inlet valve and inlet valves A and B. When air is detected, the system is paused so that the air can be removed before further introduction into the flow path. During sample application, the air sensor detects when the sample has been completely injected so that the method can continue to the next step without air being introduced into the flow path or column.

up to 4 Solenoid valves

–Enable automatic change between different buffers and wash solutions. The outlet valve for automation fraction. 

Dynamic mixer: 

–0.6ml,1.4ml,2ml,5ml,15ml Chamber, The mixer ensures homogeneous buffer composition during gradient runs. The mixer chamber size depends on the flow rate and buffers used, with a larger mixer volume required for higher flow rates or difficult-to-mix buffers. The mixer is also easily changed by snapping it in or out of the mixer holder.

image14

UV Detector OEM Kit -Fixed wavelength

Features and Benefits

  

  • LED Lamp, Lamp lifetime exceeds 8000 hours
  • Double beam optical Design, Low drift
  • Noise:± 0.02mAU 
  • Drift:<0.5mAU/Hr
  • Low Dead volume
  • 2.2uL @ 2mm Optical Path
  • 4uL @ 5mm Optical Path
  • 8uL   @ 10mm Optical Path

Model:

415nm / 280nm / 260nm /255 nm.

image15

Dual Fixed wavelength UV Detector

 This UV detector uses splitting technology to continuously measures dual-wavelength UV absorbance simultaneously. High-precision lock-in amplifier circuit is used to achieve extremely low noise and good drift characteristics. Standard SMA905 fiber optic interface and for easy integration into users measurement systems. A variety of communication interfaces are available, including RS232/RS485/USB/CAN. The structure can be customized according to user needs.    


  Features and Benefits:


  • Multi wavelength selectable
  • No lamp warm-up time allowing lamp on-off function. Long life UVC LEDs are used as light source
  • Dual wavelength simultaneous detection
  • Accurate and reliable monitoring through self-test, self-calibration and fiber optics 

  

  • Communication: RS232/RS485/USB/CAN…
  • SMA905 fiber optic interface
  • Dual  Wavelength
  • LED Lamp, Lamp lifetime exceeds 8000 hours
  •  Double beam optical Design, Low drift
  • Low Dead volume
  • Noise:± 0.02mAU 
  • Drift:<0.5mAU/Hr
  • 2.2uL @ 2mm Optical Path
  • 4uL @ 5mm Optical Path
  • 8uL  @ 10mm Optical Path

Model:

two fix wavelength in range :

415nm /340nm/310nm'mn/ 280nm / 260nm /255 nm.


image16

pH Process Detectors

Features and Benefits:

  

Process pH sensor

Applications

  • Fast protein chromatography system
  • Bioprocess chromatography

ScipH Features

  • Low dead volume
  • Wide range applications
  • Biocompatibility

  

Specifications

Dead volume:90ul

Wide range: pH 0~14

Wetted Materials : Titanium, Glass, FFKM

Connection: 

◎UNF 10–32 2B ”Fingertights” with capillary tubing 1/16" OD

◎1/4-28UNF for 1/8 or 1/16 OD tubing

ID: 1mm or 1.6 mm

Flow Rate Max:150ml/min

Operating Pressure Max:100psi

Electrical connector: BNC Plug (Male) /Straight

Cable length: 100cm.

image17

Conductivity Process Detectors

Features and Benefits:

  

Process Conductivity sensor

Applications

  • Fast protein chromatography system。
  • Bioprocess chromatography

SciCond Features

  • Low dead volume
  •  Wide range applications
  • Biocompatibility


  

Specifications

Dead volume:20ul

Wide range: 0~1000mS/cm

Wetted Materials :Titanium, PEEK

Connection: 

◎UNF 10–32 2B ”Fingertights” with capillary tubing 1/16" OD

◎1/4-28UNF for 1/8  or 1/16 OD tubing

ID: 1mm or 1.6 mm

Flow Rate Max:150ml/min

Operating Pressure Max:5Mpa

Electrical connector: BNC Plug (Male) /Straight

Cable length: 24 in.    (

image18